Vista 20P Features Eight on-board hardwire zones standard (15 when Zone Doubling feature is used) Expandable to 48 total zones when used with hardwired and/or wireless expansion modules Wireless keys can be programmed without using zones 16 output devices Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or X-10® devices (when used with a 4300 Transformer) Two low current on-board trigger outputs 100 Event Log viewable at system keypads with time/date stamp 48 system user codes assignable to either partition Two independent partitions plus a common partition Global Arming from any system keypad Goto function to view or operate one partition from the other Separate partition account numbers
Multiple actions on output devices depending on system "state" Turns lights off when system arms Turns the same light on when system disarms Flashes same lights when system is in alarm Supports four-wire, and up to 16 two-wire smokes Works with Sentrol CleanMe maintenance signal
Valuable End User Features Now viewable on system keypads: Exit countdown Time and date display* Event log* Auto keypad backlighting on entry Keyswitch arming Programmable macro buttons and single-button arming
| Electrical Seven hour standby at 400mA aux. load with four amp hour battery 16.5VAC/25VA transformer Alarm output 12VDC, 2.0 amps maximum
Output Control Zones Expansion Devices 4219 Eight hardwired zones 16mA 4204 Up to four relays 15mA standby (each active relay draws an additional 40mA) 4229 Eight hardwired zones and two relays 36mA (each active relay draws an additional 40mA)
Accessories 4286 VIP Voice Module 220mA 5881ENL RF Receiver supports up to eight zones 60mA, 5881ENM supports up to 16 zones 50mA, 5881ENH up to 40 zones 50mA 5883 Transceiver supports up to 40 zones 80mA Supports Eagle 1225 and 1221 boards