Intellesense FG-1625F Flush Mount Glassbreak Detector
The new FG-1625F Glassbreak Detector uses the latest technology to
provide faster response and increased false alarm immunity. The FG-1625F is
specifically designed to allow fast, easy installation, while the adjustable sensitivity
settings can compensate for the acoustics of any room. Optimum operation can be quickly
verified using the FG-701 Glassbreak Simulator. The FG-1625F was designed to
adequately cover all sizes of single gang electrical boxes. Flush mount installations are
now easier and better looking than ever.
Features
FlexCore™ Signal Processor
The FlexCore™ Signal Processor is an Application-Specific Integrated Circuit
(ASIC), which processes sound data in parallel rather than sequentially; for faster, more
accurate detection decisions. The combination of proven FlexGuard® performance with the
speed of FlexCore processing provides unmatched false alarm immunity without compromising
detection.
Easy Installation and Setup
IntelliSense’s patented technology allows remote activation of Test Mode (with
simulator). The FG-1625F has 45° terminal blocks for easier wiring. A hand-clap feature
verifies that the detector is functioning.
Selectable Sensitivity
Two dip switches on the FG-1625F make it easy to set the sensitivity to match the
acoustics of the room. Four different sensitivity levels are available, ranging from very
low to high. The range can then be verified remotely with the FlexGuard FG-701 Glassbreak
Simulator.
Mount the Detector Anywhere
Mounts on any wall, or on the ceiling, with no minimum range and a maximum range of 25’
(7.6 m) to the glass. The FG-1625F fits a standard single gang electrical box; while the
FG-1525FD version is specifically designed for double gang boxes.
Covers All Glass Types
The FG-1625F works on all glass types, including plate, tempered, laminated, wired,
film-coated, and sealed insulating.
Multiple Domain Signal Analysis
The FG-1625F performs Multiple Domain Signal Analysis in which time, frequency and
amplitude characteristics are evaluated for signal qualification. This enables the
detector to accurately discriminate false alarms from true glassbreak events.
Enclosed PC Board
The PCB is protected from potential damage during installation.
Patented Remote Test Mode
The Patented Remote Test Mode can enable or disable the indicator LEDs using the
FG-701Glassbreak Simulator. The unit automatically resets from Test Mode in five minutes.
Mounting Locations
The FG-1625F can be mounted on the ceiling, opposite wall, adjoining wall, or the same
wall as the glass.
Specifications
Physical Dimensions:
White high impact ABS plastic housing
Faceplate:
4.50" x 2.76" (114 mm x 70 mm)
Rear cover:
2.65" H x 1.80" W x 1.20" D
(67.4 mm x 45 mm x 30 mm)
FG-1525FD (for doublegang)
Faceplate:
4.49" x 4.49" (114 mm x 114 mm)
Rear cover:
2.65" H x 1.80" W x 1.20" D
(67.4 mm x 45 mm x 30 mm)
Weight:
Product only:
FG-1625F 3.1 oz (87g)
FG-1525FD 3.8 oz (107g)
Packaged Product:
FG-1625F 4.7 oz (133g)
FG-1525FD 6.5 oz (184g)
Range:
25’ (7.6 m) maximum, omnidirectional.
Range is adjustable; no minimum range
Alarm Relay:
Form A, 125 mA max, 25 VDC max
Tamper Switch:
Cover removal tamper 25mA max, 24VDC max
Alarm Duration:
5 seconds (unaffected by alarm LED latching)
ESD Immunity:
10kV discharges of either polarity to exposed surfaces
Power Requirements:
6-18VDC; 12mA typical at 12VDC, 22mA max.
AC Ripple: 4V peak to peak at nominal 12VDC
RFI Immunity:
30 V/m, 10 MHz - 1000 MHz
Operating Temperature:
14° to 120° F (-10° to 50° C)
Storage: -4° to 122° F (-20° to 50° C)
Approvals and Listings:
FCC and IC verified
UL Listed
ULC Listed
C-Tick
CE
Glass Type/Thickness
Type* |
Minimum |
Maximum |
Plate3a |
2.4 mm (3/32") |
10 mm (3/8") |
Tempered |
3 mm (1/8") |
10 mm (3/8") |
Laminated1 |
3 mm (1/8") |
14 mm (9/16") |
Wired |
6 mm (1/4") |
6 mm (1/4") |
Coated2,
3b |
3 mm (1/8") |
6.4 mm (1/4") |
Sealed |
3 mm (1/8") |
6 mm (1/4") |
Insulating1, 3b |
(Maximum overall
7/16") |
* Minimum size for all types is 28 cm (11") square; glass must be
framed in the wall or mounted in a barrier at least 0.9m (36") wide.
1 Protected only if both plates of
the unit are broken.
2 Coated glass with security films,
including films for solar protection, up to 12 mil. thick may be used. Film Technologies
International, Inc.’s GLASS-GARD® GGLL 1200 has been evaluated with this product by
Underwriters Laboratories, Inc. at the request of IntelliSense.
3 In compliance with Underwriters
Laboratories of Canada’s Standard for Intrusion Detection Units
(CAN/ULC-S306-M89):
3a Plate glass 3mm to 10mm can be used.
3b ULC recognizes a maximum range
for protecting sealed insulated glass and coated glass of 12.5 ft. (3.8 m).
Note: The FG-1625F detects shattering of framed glass by direct
impact. It may not consistently detect breakage by blows that only crack the glass, by
high velocity projectiles such as bullets, or glass broken without an impact.
Accessories Description
FG-701 P/N 0-000-701-01 ? Glassbreak Simulator
FlexGuard® Glassbreak Simulator/Tester
The sound of breaking glass is digitally simulated by the FG-701. The FG-701 is
compatible for testing all IntelliSense glassbreak detectors. IntelliSense highly
recommends testing glassbreak detectors before final installation.
|