Changes to 2.09 From 2.08 1) Made so status is checked at connect even if no program log. This is so Last Diagnostic date on single customer, and the entire row on the list, will be red if a system service condition exist. Zone service conditions, such as tampers, will not cause this. 2) Added new location for report partition to card reader and door control 3) Fixed bug where NX-8ECF did not show Sprinkler Supervisory as an option on zone type page 4) Fixed bug where, if panel type is changed in customerlist, and data is copied, until selected account is changed no other changes to database are reflected. 5) Store position of cancel dialog for download secession. Not between sessions 6) Corrected zones in NX-8ECF only showing 48 Changes to 2.08(2.07 was only released as beta) From 2.06 1) Fixed problem where user cannot change their own password. 2) Corrected loading of descriptors for page 2 for 148E. Was always loading 48. 3) Corected problem when adding tabs when changing from 591 to 580, new tabs weren't displayed correctly. 4) Print names with 1700 and 1710 5) Added code to limit serial numbers printed to users sent/read.(CardReader and Door control) 6) In Customer printout, corrected issue where accounts were printed multiple times if no address printed 7) Corrected problem importing modules, from DOS database, created in version 2.00. 8) Corrected issue when downoading 591, and module was not already in database 9) Added options for different lockouts for auto download 10) Added batch mode to allow changes to be easily put into several accounts. Select multiple accounts from customer list before selecting batch changes. 11) Added authority to operators to use batch mode. This authority is initially off for all 12) Added option to create account if not found when panel calls in for auto answer. If customer account exists, will add date and time to end of account number to make it different.("account MM DD YY HH mm") If account is created, you must stop auto answer to see new account 13) Corrected bug causing location 193,194, and 195 not to be written on write all on 448E. 14) Corrected defaults on CF panels 15) Added code to display message that TCP/IP module is updating, please wait. This will be displayed for 1 minute. 16) Fixed bug causing error to not be detected during auto answer session 17) Added ability to change languages on NX-540 (Italian and Spanish) 18) Allow saving of changes to last 4 options on keypad options 19) Added buttons for program log and read 10 events from event log 20) Added Spanish and Italian defaults to 540 21) Changed the Door control and Card reader serial numbers to user change and read authority to enable or disable the screen 22) Fixed bug where I do not show '*' for non reporting events on event log printout 23) Test service condition at connect/disconnect if using program log. 24) Remove "Test service condition" from Auto-answer options since it is tested at connect/disconnect if program log is used 25) Allow only 1 account or multiple accounts to be selected for batch mode 26) Added First to open/Last to close to NX-8E 27) Added option to clear all auto-download options, or just auto-selected ones 28) Added right click menu to Auto-download tabs to clear all options Changes to 2.06 From 2.05 1) Corrected problem in detecting wireless receiver types that was created in 2.05. This problem would not allow writing to any type of wireless receiver Changes to 2.05 From 2.04 1) Corrected problem causing connect menu to be disabled after Auto-answer mode exited. 2) Corrected problem where fire zones show as bypassed of Fire panels. 3) Corrected problem where when changing to new version of 590, new tabs were not automatically added. 4) Corrected problem where when changing from different types of wireless receivers during download, program would crash 5) Corrected problem where when changing from 580 to 591, or visa-versa, during download, program would crash 6) Changed so that starting zone, on receiver settings tab, will be disabled on NX-448. This is to help avoid confusion. This is not used on the 448. Only on 408 and 416. 7) Corrected problem causing connect menu to be disabled after canceling Answering machine defeat. Changes to 2.04 From 2.03 1) Added NX-8ECF 2) Corrected problem when exporting database with no destinaton database. Problem was created in 1.17 causing newly created database to not have Operator Group data loaded. This disabled importing of this into a different database if passwords are used. 3) Corrected printout for NX-8 CF. 4) Added "Fire only on 870" to System options for NX-8CF 5) Corrected reading/writing of user codes in NX-6 and NX-4 during auto answer. 6) Corrected logic of read/write all for auto-answer. 7) Now support auto-answer via TCP/IP 8) Made so if all keypads checked, text is checked as well. 9) Enable enroll for all connections. (Was disabled for direct connect/TCP/IP) 10) Changed so that when doing read/send module from options screen, text is excluded. Changes to 2.03 From 2.02 1) Corrected importing of window's database when a password is required. 2) Disable ReadSection on Holiday/code page in NX-508 and new NX-1700 if not online 3) Changed X-10 on all modules to use combo boxes listing 1-16 and A-P 4) Corrected problem in NX-2192 causing output 8,16,32,... to never be enabled in printout. Changes to 2.02 From 2.00 1) Corrct strings on Names page for NX-590 2) Corrected issue where serial numbers were not always read when selecting Read module from serial number screen 3) Changed to sort Last name, First name when selecting Goto button beside customer name 4) Corrected problem where LCD options were not included in Read/Write all if Keypad was 148E, 1192, or 1248 Changes to 2.00 From 1.17 1) Corrected bug causing "Invalid Index" displayed on old card reader. Created in 1.17 2) Corrected name using wrong index to store name in Card Reader Created in 1.17 3) Finished adding new version of NX590 4) Corrected bug not saving partition enables in 590 correctly 5) Corrected issue where options screen would not add tab when custom message locked. 6) Corrected programming of 2192 points. 7) Added NX-208E 8) Added selection for 1248. Supported in version 1.12, but not a seperate selection. 9) Corrected bug in 590 causing old version not to download 10) Corrected bug in 1700 causing new version not to download 11) Corrected bug not saving partition enables in 591 correctly 12) Corrected bug ,created in 1.17, causing zone text not to show on zone screens. 13) Corrected Function not getting updated if only it is changed. (NX-540) 14) Corrected night mode Changes to 1.17 From 1.15.1 1) Combined Download options, Auto-callback options, and Account options into 5 tabs under Download options to allow user to select all download option settings in one location. 2) Added ability of software to send/read sections when doing an auto-download.(for example: User codes, Account info, partition...) 3) Added ability of the software to enable sending of different sections automatically when data on screen is changed. 4) Added ability to automatically clear the section selected for a given acount once the auto-download session is succesfully completed. 5) Added several fields to the customer screen. These new fields are only visible on the Single customer screen, and are viewed by selecting "Additional items >>" 6) Added ability to test siren from download. 7) The service condition of the control is entered in the program log when the keypad status is viewed 8) Changed how bypassed zones are determined to make loop more efficient and allow dashes to be used for ranges 9) Added Test service for auto download. DO this anyway if test siren is enabled 10) Modified Add/Change operators to now have groups with certain authority, and operators assigned to a group. When upgrading existing databases I will use the following rules: A) Any user with master access authority will be assingned to an "Administrator" group B) If multiple users currently have master access, and all other options are the same, they will be assigned to the same group. If some options are different, subsequent operators will be assigned to "Administrator1","Administrator2"... C) operators without master access, will be assigned to a "User" group D) If multiple users currently do not have master access, and all other options are the same, they will be assigned to the same group. If some options are different, subsequent operators will be assigned to "User1","User2"... 11) Added ability to select multiple accounts(max of 10) as "Default accounts". These accounts can be copied, but not edited unless the operator has Master access authority, and selects "Edit default accounts" from the tools menu. 12) You can no longer download to a panel that is a default account other than to send to a slot in the NX-586E 13) Now will search by and sort by First name, last name in on single customer screen when searching for customer name. 14) Added menu to allow send/read of control panel to control panel screens. 15) Corrected where read/write all would not work for anything if callback was used and auto select account was enabled. 16) Do not reset event log pointer in auto answer if panel is a NX panel. 17) Corrected help on NX-1700E 18) Include partition 1 account in read/write for NX-4 19) Added code to allow keypad status on TCP/IP connect 20) Finished adding new version of cardreader(NX-1702E) 21) Put test to see if year was decremented while reading event log, so that evenmts from previous year that are more than one year old would have correct year. 22) Corrected bug where if there was an error on a previous read/write, Keypad status would crash. 23) Corrected stop keypad sounder/siren so that it will be disabled if the siren or sounder is not on. 24) Do not enter program mode for direct connect. Enter and exit program mode at end of direct connect. 25) Log start/end download when connecting via TCP/IP Changes to 1.15.1 From 1.15 1) Corrected minor issues in foreign builds. Changes to 1.15 From 1.14.5 1) If user of DL900 has authority to change arm/disarm codes, but not read them, will now display screen with arm/disarm codes shown as ****. In previous versions, the screen would not display at all 2) Added support for fire panel (NX-8CF) Changes to 1.14.5 From 1.14.4 1) Corrected No curent record error in Operator List Changes to 1.14.4 From 1.14.3.5 1) Corrected problem where keypad 1, partition 8 would show as keypad 1, partition 0 in device list 2) Added option for print event log as displayed to allow printing exactly as read from panel 3) Now can export to a database that doesn't exist. Will create it Changes to 1.14.3.5 From 1.14.3.1 1) Made so you can select whole row on diagnostics and event log 2) Added encryption to TCP/IP connect 3) Changed modem screen to have Add modem button, not save changes 4) Added database version to about box Changes to 1.14.3.1 From 1.14.3 1) Corrected problem on Win 95 where program would not start when upgrading. Error was "Incorrect parameter". Changes to 1.14.3 From 1.14.2 1) Corrected problem where menus were displayed on backup screens in Windows NT/2000 2) Added support for Night mode. 3) Added module type descriptions to modules enrolled list. 4) Moved modules loaded list to Copy options screen 5) Corrected printout/screens for NX-590 6) Added feature where selecting module from enrolled dropdown will activate screen for that module Changes to 1.14.2 From 1.14.1 1) Corrected problem where output number was not entered in event log for output tripped/restored. This was crested in 1.14 2) Added Find location in view menu Changes to 1.14.1 From 1.14 1) Changed LCD custom text for applicable installations. (no effect on standard installations) Changes to 1.14 From 1.13 1) Changed printouts to have comma after city not state 2) Added ding dong chime to Card reader 7) Moved menu from customer screens to main view menu. 4) Corrected hot keys while modules have focus 5) Changed some hot keys.. 6) Added hot keys for keypad status. 7) Changed Copy options to Ctrl Y. 8) Added button for keypad status 9) If corect port not found, select first modem list. 10) Added callback to TCP/IP connect 11) Now get keypad status from direct connect 12) Remember position of event log, keypad status 13) Keypad status is resizable in width only 14) Get TCP/IP adress of computer from DL900 15) Now if no language selected for LCD, use computer settings 16) Changed transmitter ID's 17) Will allow ID input with bar code scanner 18) Added NX-591, and NX-590 19) Changed so if name or output desc is blank, will not import from DOS 20) Clean up user name table and output descriptor table to get rid of duplicate backups 21) Log "Event log read" in Program log 22) Added prompt if trying to delete blank account 23) Added menu option under Download>>Device list labeled "Create module entries" this will read all enrolled version info, and create the correct database entries. 24) Made card reader(1700) serial numbers be determined by number of users in panel